API integration reference

Each feature lists the exact call, what goes on the wire, and what counts as an answer. Source: PayloadSDK fba3c70 (SDK_VERSION 3.2.0_build.15082026). SDK methods return void, so calling one proves nothing: Analyze › Commands shows the observed frame and the answer separately.

Object detection

Three kinds of thing are involved: Gremsy SDK API (regPayloadDetectionChanged, sendPayloadRequestStreamRate, setPayloadCameraParam), standard MAVLink (MAV_CMD_SET_MESSAGE_INTERVAL, V2_EXTENSION), and application side (validation, states, overlay, selection). The packet format inside V2_EXTENSION is Gremsy's.

Commands

Action App call SDK call On the wire Answer
Enable, step 1 PayloadLink::detectionEnable() setPayloadCameraParam("TRACK_MODE", 1, PARAM_TYPE_UINT32) PARAM_EXT_SET, followed by a read-back PARAM_EXT_REQUEST_READ PARAM_EXT_ACK
Enable, step 2, 500 ms later (the example's delay) same sendPayloadRequestStreamRate(248, 100) COMMAND_LONG MAV_CMD_SET_MESSAGE_INTERVAL, param1 = 248, param2 = 100000, to compid 26 COMMAND_ACK, then the packets
Stop stream detectionStop() sendPayloadRequestStreamRate(248, 0) as above, param2 = 0 COMMAND_ACK, then silence
Disable (button) detectionStop(), then cameraParam() as above, then setPayloadCameraParam("TRACK_MODE", 0, ...) as above, then PARAM_EXT_SET PARAM_EXT_ACK

The SDK comment says rate 0 stops the stream. Standard MAVLink defines param2 = 0 as "default rate" and -1 as "disabled", so whether 0 stops it is firmware behaviour. hw_vio_commands --steps detection checks it.

TRACK_MODE has the same ID and values in vio_sdk.h, zio_sdk.h, mb1_sdk.h and orusl_sdk.h: 0 tracking, 1 detection.

Packet

V2_EXTENSION with message_type 0x4001, payload det_packet_t (libs/detection_packet.h): magic 0x4744, version 1, num_boxes, frame_id, then up to 20 boxes of 12 bytes.

Field Meaning
x, y Top-left corner, in 1920×1080 reference pixels
w, h Size, same space
track_id 0 = no track assigned yet
class_id Depends on the model loaded on the payload. The video overlay shows the number only. The data window adds a name marked as a guess: the SDK example's COCO table applies only to its EO model, and it warns that IR IDs differ
confidence 0–255 = 0–100%

The packet has no timestamp and no video frame reference.

Validation

Layer Check
App frame parser (for the inspector) and SDK parser MAVLink CRC with the V2_EXTENSION CRC extra
SDK _handle_msg_v2_extension() message_type, magic, version, clamps num_boxes to 20
parseDetectionPacket() Rejects a box with zero width or height, an origin outside the frame, or a size above the frame's. Clips one that only overruns the edge. Counts rejected boxes, including any claimed above 20

No payload-length check exists, and none is needed. MAVLink 2 trims trailing zero bytes from every frame, and mavlink_msg_v2_extension_decode() zero-fills them again. So:

  • A short frame is normal: a packet whose last box ends in zeros is legitimately shorter, and rejecting it would drop good data.
  • A box the wire did not carry reads as all zeros, so w = h = 0 rejects it. A header cut short fails the magic or version check.
  • The SDK's fixed memcpy copies 248 bytes from a 249-byte zero-filled array, so it cannot over-read.

The callback therefore loses nothing by not exposing the length, and no SDK patch was added. Tests cover each case with real frames through the real SDK parser.

States

State Meaning Cause
Off Support unknown Not enabled from here, no packets
Waiting Enabled, no packet yet, under 5 s
No response Enabled, no packet after 5 s
Active, nothing detected Packets arriving with 0 valid boxes
Active Packets arriving with boxes
Stale Packets stopped for over 1.5 s (the example's DET_TIMEOUT_MS) while enabled. Boxes and selection are removed
Refused TRACK_MODE or the stream request got a rejecting ACK and no packets arrived

An ACK timeout is not a refusal: it ends in No response. Packets arriving without an enable from this app count as Active, because that is what the payload is doing.

Selection and the tracker

  • A click on a box selects it by track_id, only while the tracker is not armed. Selecting sends nothing. Boxes with track_id 0 cannot be selected, because nothing identifies them across packets.
  • The panel shows the box's centre and size, which is what trackingTarget() would take. A box's x, y is the top-left corner, trackingTarget() takes the centre, and the TRK_POS_* the tracker reports is top-left again.
  • trackingTarget() takes coordinates and a size. It has no way to name a track_id.

Forwarding to the tracker is not implemented. What the sources establish:

Question Evidence Answer
Can detection and tracking run together? One parameter with two values in all four headers. demo_project turns detection off by setting tracking mode Treated as exclusive; not proven by hardware
Does the tracker accept a target after switching back? Nothing in the SDK Unknown: --steps detection-forward tests it on a VIO
Are target semantics the same per model? Centre and size verified on VIO 3.1.4.18 only. Tracking was last run before 3.1.8.21 Unknown for ZIO, MB1, OrusL, and for VIO 3.1.8.21

To keep the two apart, Select target stops the detection stream before its unchanged sequence, and Enable detection first stops an armed tracker, so a later click cannot send a target by accident.

Data window

Application side, read-only: the Detection data… button in Operate › OBJECT DETECTION opens a separate, non-modal window. It sends nothing.

Part Content
State The same state as the panel. Stays live while paused
Summary Frame ID, valid and claimed boxes, age of the last packet, packets per second over the last 2 s
Newest packet Track, class, confidence, x, y, w, h, centre. Empties when packets go stale
Log Last 1000 packets, newest first: receive time, frame ID, box count, invalid count
Pause Freezes the table and log. Packets keep being recorded and appear on Resume, up to the 1000 limit
  • Receive time is this PC's clock when the SDK delivered the packet, because the packet has no timestamp.
  • Class: 3 (motorcycle?) is the number plus a guess from the SDK example's COCO table. An ID above 79 shows only the number. The guess is yours to judge against the picture: it can be wrong on IR or on another model.
  • Invalid boxes appear only as a count, not as rows.
  • The log is cleared on connecting. It stays readable after a disconnect while the window is open; the button itself is disabled while disconnected, like the rest of the panel.

Limits

  • Only the EO view is used by the SDK's example. In other views (IR, picture-in-picture, side by side) whether the coordinates fit the picture is unknown; the panel warns when the payload reports another view.
  • Disconnecting leaves TRACK_MODE and the stream as they were on the payload, the same way tracking is left.
  • The firmware needed for detection is not documented anywhere in the SDK.

Stream and FOV telemetry

Read-only. SDK API for the requests, standard MAVLink for the messages, application side for the display.

Action App call SDK call On the wire Answer
Stream requestStreamAndFov() getPayloadCameraStreamingInformation() COMMAND_LONG MAV_CMD_REQUEST_VIDEO_STREAM_INFORMATION, param1 = 0 (all), to the camera VIDEO_STREAM_INFORMATION
FOV same getPayloadCameraFOVStatus(CAMERA_EO), (CAMERA_IR) COMMAND_LONG MAV_CMD_REQUEST_MESSAGE, param1 = 271, param2 = 0 or 1, to the camera CAMERA_FOV_STATUS
  • Workflow: the button sends tracked requests. While Analyze › Telemetry is open, pollStreamAndFov() repeats them every 2 s without adding to the command log, once the camera has been heard (before that the SDK addresses the wrong component). The SDK's own FOV example polls at 2 Hz.
  • Response and ACK are separate: the requested message gives the state Answered; a COMMAND_ACK is recorded on top. One reply answers one request. An unanswered request ends in No ACK (timeout).
  • Display: values come from CRC-valid received frames. They show only while the newest reply is younger than the link timeout (at least 3 s, since replies come at most every 2 s). After that only the age is shown.
  • Bitrate: taken from the received message. getPayloadStreamBitrate() is not used, since it always returns 0.
  • EO-only models: the IR request is not sent, so ZIO asks only for EO.
  • Not assumed: param2 for FOV is a Gremsy use of a standard field. How camera_device_id in the reply maps to EO and IR is unverified, so the raw number is shown. MAVLink defines 0 as "a MAVLink camera", so EO and IR replies could share an ID, in which case the newer one replaces the older.

Image calibration

Custom Gremsy commands. All are COMMAND_LONG MAV_CMD_USER_4 to the payload core (compid 26), with the unused params 0.

Control App call SDK call param1 param2 param3
FFC auto irFfcMode(true) setPayloadCameraFFCMode(FFC_MODE_AUTO) 2 6 1
FFC manual irFfcMode(false) setPayloadCameraFFCMode(FFC_MODE_MANUAL) 2 6 0
Trigger FFC irFfcTrigger() setPayloadCameraFFCTrigg() 2 7 0
WB one push eoWbOnePush() setPayloadCameraWBOnePushTrigg() 2 8 0
  • Feedback: COMMAND_ACK in Analyze › Commands. COMMAND_ACK names only the MAV_CMD, so answers to several USER_4 commands in flight are matched oldest first and cannot be told apart. Send them one at a time when checking a result. An accepted ACK says the command was accepted, not that the picture changed.
  • FFC mode read-back: getPayloadCameraFFCMode() has an empty body and is not called. irFfcMode() starts the FFC_MODE DEBUG stream (setParamRate(PARAM_CAM_IR_FFC_MODE, 1000)), shown under Payload reports. There is no read-back for a trigger or for one-push.
  • Model support: FFC needs an IR camera, so ZIO has it disabled. One-push is enabled where the header defines PAYLOAD_CAMERA_VIDEO_WHITE_BALANCE_ONE_PUSH, so MB1 has it disabled. The SDK itself gates neither command per model.
  • Not assumed: the SDK's FFC example selects the IR view first; the app does not change the view. Whether one-push needs White balance = One push first is undocumented.

Gimbal settings

The standard MAVLink parameter protocol, through the SDK API, on its own page: Analyze › Gimbal settings. It never sends motion or mode commands.

Action App call SDK call On the wire Answer
Read gimbalSettingsRead() getPayloadGimbalSettingList() PARAM_REQUEST_LIST to the gimbal One PARAM_VALUE per parameter
Write gimbalSettingWrite(id, value) setPayloadGimbalParamByID() PARAM_SET: the ID, the value as a float, param_type 0 No ACK exists
Read back automatic after a write getPayloadGimbalSettingByID() PARAM_REQUEST_READ, param_index -1 PARAM_VALUE
  • Response format: PARAM_VALUE has param_id (16 characters, not terminated at full length), param_value as a float, param_type, param_index, param_count. Only frames from a gimbal component (154, 171–175) are stored. The page shows N of M received, because replies can be lost. Reading again fills the gaps.
  • Feedback: the command log says Sent (no ACK defined). The only confirmation is the value in the table changing.
  • Guards on a write:
    • The operator confirms a dialog naming the parameter, the new value and the reported one.
    • The ID must have been read from the gimbal.
    • The value must fit the reported type. It travels as a float, so integers beyond 2^24 and unknown types are refused.
    • A 16-character ID is refused, because setPayloadGimbalParamByID() copies it with strcpy into a char[16]. Those parameters can be read, not written.
    • The selection is held by ID, so a row moving while the list arrives cannot change what gets written.
  • Not known: ranges (the SDK documents none; its example writes STIFF_TILT = 50), whether a value is stored across restarts, and which parameters each model has. The list comes from the gimbal, so no per-model table exists.
  • Not exposed: sendPayloadGimbalCalibMotor() sends MAV_CMD_DO_SET_HOME with param7 = 1, which does not match its name. Calibration and auto-tune were not requested.

Stream bitrate

Control App call SDK call On the wire Answer
Operate › SETTINGS › EO bitrate, IR bitrate streamBitrate(cam, bps) setPayloadStreamBitrate(cam, bps) COMMAND_LONG MAV_CMD_USER_4 to compid 26: param1 = 4, param2 = 2, param3 = cam (1 EO, 2 IR), param4 = 0, param5 = bps COMMAND_ACK; new value in VIDEO_STREAM_INFORMATION
  • Values: fixed presets from 0.512 to 16 Mbit/s. That range appears only in the SDK example's help text. A float holds every value exactly.
  • Confirming it: the ACK says only that the command was accepted. Analyze › Telemetry shows the bitrate the payload reports.
  • Not known: whether the value survives a restart, whether RTSP or RTP/TS keeps playing, and whether the IR value applies to the current view. The app does not restart video by itself: if the stream drops, it shows the error and waits for Play.
  • Tested only against the fake payload.

Not built

These stay out until the stated question is answered. The encodings below are from the SDK source; none has been sent by this app. All are COMMAND_LONG MAV_CMD_USER_4 to compid 26.

Function SDK call param1, param2, param3, param4, param5 Waiting for
Stream resolution setPayloadStreamResolution(cam, level) 4, 2, cam, 1, level The level list (the example shows only level 1: EO 1920×1080, IR 640×512), persistence, recovery
Stream profile setPayloadStreamProfile(cam, profile) 4, 2, cam, 2, profile The profile list (the example shows only 1 = Balance), persistence, recovery
Standby setPayloadStandbyMode(on) 4, 3, 0, on, 0 What stops working, and how to recover. Disruptive
Restart an app setPayloadRestartApps(id) 4, 4, id, 0, 0 (0 payload, 1 streaming, 2 tracking, 3 web UI, 4 gimbal) Link and video recovery per app. Disruptive
OrusL SpotAE setCameraExtSettings_SpotAE_* 4, 5, 0 display / 1 mode / 2 position, then values An OrusL unit, and the value meanings
GPS, time sendPayloadGPSPosition, sendPayloadGPSRawInt, sendPayloadSystemTime Standard messages, not USER_4 An autopilot input source, which the app does not have. Sending invented positions would be worse than none

The stream functions number cameras 1 = EO, 2 = IR, while getPayloadCameraFOVStatus() uses camera_type_t 0 = EO, 1 = IR, so the two must not share a constant.

The app already reads the current bitrate, resolution and profile-independent stream data from VIDEO_STREAM_INFORMATION (see Stream and FOV telemetry), so a later resolution or profile write can be confirmed from a received message.